10/100 Managed 24-Port GigaSwitch
BRIDGING
If you select Bridging from the Advanced Management screen, the following
Bridging Parameters screen will appear.
1. To change the aging time, highlight Aging Time <seconds> and press
Enter. The following prompt will ask you to enter a bridge aging period,
in seconds. Enter a new aging period and press the Enter key. Enter 0 for
no aging.
2. To change the flood limit for all ports, highlight Flood Limit for All ports
<pkt/s>, the following prompt will ask you to enter the flood limit,
in packets per second. Enter a a new flood limit and press the Enter key.
Enter 0 for no limit.
3. Press the Esc key until you return to the desired screen.
57
Linksys EtherFast
®
II Series
5. Type a packet count number from 1 to 999, or type 0 for an infinite packet
count. Press Enter.
6. Move to Size <mbytes> and press Enter. The Enter Packet Size screen
will appear.
7. Type the packet size, from 0 to 1500, then press Enter.
8. Move to Timeout <sec> and press Enter. The Enter Timeout screen will
appear.
9. Type a timeout value, from 0 to 999, and press Enter.
10. When you finish specifying the ping parameters, press Esc to start ping-
ing a remote IP address.
11. Press Esc again to return to the L3 IP Networking screen.